Cardiac biomarkers are used in the diagnosis and risk stratification of patients with chest pain and suspected acute coronary syndrome (ACS).

In patients with ACS, cardiac ischemia and other heart conditions associated with insufficient blood flow to the heart, these biomarkers are absolutely critical indicators to determine if a paitent is experiencing an acute miocaridial infraction (MI) or heart attack.

RYVEX understands the need for reliable, robust and efficient testing and have added the following to our portfolio:

Standard F Series of Analysers

STANDARD F is a multi-parametric and random accessible FIA system providing accurate diagnostic results to your laboratory.

STANDARD F100 Analyzer

This small fluorescence immunoassay device can perform qualitative and quantitative analysis on infections, respiratory diseases and chronic diseases, and it is operable with battery

STANDARD F200 Analyzer

This fluorescence immunoassay device that can perform qualitative and quantitative analysis on infections, respiratory diseases and chronic diseases supports convenient user interface and LIS/HIS connectivity.

STANDARD F2400 Analyzer

This fluorescence immunoassay device that can perform qualitative and quantitative analysis on infections, respiratory diseases and chronic diseases supports convenient user interface and LIS/HIS connectivity.

A more comparative overview can been seen in this table below:

CKMB

STANDARD F CK-MB FIA is a fluorescent immunoassay for the quantitative measurement of Creatine Kinase Isoenzyme-MB level in human serum and whole blood. This test is to screen and monitor the Acute Myocardial Infarction (AMI).

Specimen Serum, Whole blood
Sample volume 100µl
Range 1~200ng/mL
Time 15mins
Temperature 2-30? / 36-86?
Shelf life 18 months

Requires Standard F Analyzer system 

Troponin I (TnI)

STANDARD F TnI FIA performs quantitative measurement of Troponin I (TnI) level in plasma and whole blood samples using fluorescence immunochromatography. Through the STANDARD F Analyzer, test results with high sensitivity and specificity can be obtained

Specimen Serum, Whole blood
Sample volume 100µl
Range 0.05-20.0ng/mL
Time 15mins
Temperature 2-30? / 36-86?
Shelf life 18 months

Requires Standard F Analyzer system 

NT-proBNP

STANDARD F NT-proBNP FIA is a quantitative test for the determination of the N-terminal pro brain-type natriuretic peptide (NT-proBNP) level in human serum and whole blood(EDTA).

Specimen Whole blood (EDTA), Serum
Sample volume 100µl
Measurement Range 0 ~ 25,000pg/mL
Time 15mins
Temperature 2-30? / 36-86?
Shelf life 18 months

Requires Standard F Analyzer system 

D-Dimer

STANDARD F D-dimer FIA performs quantitative measurement of D-dimer level in plasma and whole blood samples using fluorescence immunochromatography. Through the STANDARD F Analyzer, test results with high sensitivity and specificity can be obtained

Specimen Plasma, Whole blood
Sample volume 10µl
Measurement Range 25-5,000mg/mL
Time 7mins
Temperature 2-30? / 36-86?
Shelf life 18 months

Requires Standard F Analyzer system 

hs-CRP

STANDARD F hs-CRP FIA performs quantitative measurement of high-sensitivity C-Reactive Protein (hs-CRP) in serum, plasma and whole blood samples using fluorescence immunochromatography. Through the STANDARD F Analyzer, test results with high sensitivity and specificity can be obtained.

Specimen Serum, Plasma, Whole blood
Sample volume 5µl
Range 0.1-15.0mg/L
Time 3mins
Temperature 2-30? / 36-86?
Shelf life 18 months

Requires Standard F Analyzer system 